The simulator is designed to teach students the basics of electrical installation.
The simulator can be used for training in the operation of domestic and industrial electrical installations.
On the simulator stand you can conduct experiments such as:
– Electrical measurement
– Basic electrical control
– Electrical installation
– Power factor correction
– Brake system control for three-phase AC machines
– Speed control of a three-phase AC machine using an inverter
All inputs and outputs on each panel are equipped with safety connectors and 4 mm safety jumper links.
A complete guide to experimentation is included.
Composition of components:
Three-phase power supply
– Main source voltage 230/ 380 VAC, load maximum 10 A.
Three-phase circuit breaker, NFB
– Contacts: The 3 main contacts of the phase,
– Switch load maximum 15A / 15 kA,
– rated voltage of 380 VAC.
Three phase circuit breaker with RCD, ELCB
– Contacts: 4 main contacts (3 phases and 1 neutral),
– The maximum load of the breaker is 25A,
– rated voltage of 220 VAC,
– maximum leakage current 30 mA.
Three-phase circuit breaker, MCB
– Contacts: 3 phase contacts,
– maximum switch load 25A / 380 VAC,
– complete with fault simulator for L2 and L3 lines on the protection panel.
Contactor
– Contacts: 3 main contacts and 1 NO (normally open),
– switching load maximum 25 A / 380 V AC,
– coil voltage 220 VAC / 50 Hz,
– complete with fault simulator for lines L1, L2 and contact coil on the protection panel.
Power On Delay Timer
– Time delay setting range: 0.1 – 30 ms,
– contacts: 3 main contacts and 3 control contacts (2 NO-normally open, 1 NC-normally closed),
– maximum load on the switch 10 A / 380 VAC, – rated operating voltage 220VAC / 50Hz,
– complete with fault simulator for the L2 line, contact coil and auxiliary NO contact on the safety panel.
Three-phase switch
– Contacts: 3 main input contacts and 6 main output contacts,
– Switch load maximum 15A / 220 VAC
Push-button switches
– 2 pushbutton switches,
– Contacts: 2 normally closed contacts and 2 normally open contacts,
– load on the switch maximum 250 VAC / 10 A.
Switch
– Flush mounting type 250 V / 10A.
Indicator lamps
– 3-Lamp Indicator,
– color: red, yellow, green.
– Rated voltage 220 VAC
Lamp base
– Rated voltage 220 VAC
MCB single-phase circuit breaker
– 1 main contact and switch load maximum 25A / 380VAC
Power contactor
– Contacts: 3 main contacts and 4 control contacts, 2 NO-normally open and 2 NC-normally closed,
– load on the switch maximum 25A / 380 V,
– coil voltage 220 V / 50 Hz,
– complete with fault simulator for L2 line, contact coil and auxiliary NO normally open contact on the safety panel.
Thermostat I
– 3-pole, single-phase overload cutoff,
– setting range: 0.63 – 1A,
– auxiliary contacts: 1 NC-normally closed, 1 NO-normally open,
– complete with fault simulator for the L1 line and NO/NC contact on the protection panel.
Thermostat II
– 3-pole, single-phase overload cutoff,
– setting range: 2.5 – 4 A,
– auxiliary contacts: 1 NC-normally closed, 1 NO-normally open,
– complete with fault simulator for the L1 line and NO/NC contact on the protection panel.
Single switch
– Flush mount type 250 VAC / 10 A, complete with fault simulator on protective panel.
Series switch
– Flush mount type 250 VAC / 10 A, complete with fault simulator on the cover plate.
Schuko outlet
– Flush mounting type 250 V / 16 A AC, 2-pole with grounded contact.
Voltmeter
– Measuring range: 0 – 500 VAC,
– instrument: meter with moving coil, class 1.5,
– the device measures three-phase voltage.
Ammeter
– Measuring range: 0 – 10 A, instrument: moving coil meter, class 1.5,
– The device measures three-phase current.
Single phase circuit breaker with RCD, ELCB
– Contacts: 2 main contacts for phase and zero,
– Switch load max: 25 A rated voltage 220 V,
– maximum leakage current 30 mA
Fluorescent lamp bases left side
– Voltage max: 220 -250 V, 50 Hz, current max: 3 A, starter + socket: 20 – 40 W
Ballast module for fluorescent lamps
– Voltage max: 220 -250 V, 50 Hz, 20/40 W
Fluorescent lamp bases right side
– Voltage max: 220 -250 V , 50 Hz, current max: 3 A
Capacitive load
– Maximum voltage : 400 VAC
– Capacitors: 3×1 μF; 3×2 μF; 3×4 μF
Pole changer
– Max. Current: 10 A, 400 V, switch position “2 – 1 – 0 – 1 – 2
Adjustable power supply
– Max. 1A current. Output Voltage: 0 – 20VDC
Potentiometer
– Potentiometer 5 kOhm/0.25 W Adjustable potentiometer with pointer knob
Relay
– Max. Current: 10 A, 250 V, 3 contacts “NC” and 3 contacts “NO1
Counter
– Rated voltage 220 V
Inverter
– Nominal voltage 380 V, power 2 hp.
Intermediate switch
– Flush mount type 250 V / 10A AC, complete with fault simulator on the protection panel.
Single-phase electric motor
– Asynchronous motor, 0.5 hp, 4-pole, 50 Hz, 220 VAC, 450 rpm.
Three-phase AC motor 1
– Asynchronous motor, 1/4 hp, 4-pole, 50 Hz, 220 / 380 V, 1450 rpm.
Three-phase AC motor 2
– Asynchronous motor, 2 hp, 4-pole, 50 Hz, 380 / 660 V, 1450 rpm.
Three-phase AC two-speed electric motor
– Asynchronous motor, 1 hp, 2/4 pole, 50 Hz, 380 / 660 VAC, 1500 / 3000 rpm
Safety connecting wire 100 cm – 46 pcs.
Safety connecting wire 50 cm – 40 pcs.
Safety connection wire 30 cm – 27 pcs.
Cross connector – 50 pcs.
Guide to experiments 1 pc.