The simulator is designed to give students an understanding of electrical installation technology.
The system consists of several training modules that include electrical measurement, electrical installation, and electrical troubleshooting.
The simulator can be used for training in the operation of domestic and industrial electrical installations.
The technology of control and installation of electrical equipment allows you to conduct experiments such as:
– Electrical measurement
– Basic electrical control
– Electrical installation
– Power factor correction
– Troubleshooting the installation.
All inputs and outputs on each panel are equipped with a protective connector and a 4 mm protective cross-connector.
A complete step-by-step guide to the experiments is included.
The composition of the set:
Three-phase source
– Main source voltage 230/380 VAC, load maximum 10 A
Circuit breaker without fusible link, NFB
– 3 main contacts, breaker load maximum 10A/15kA,
– rated voltage of 220 VAC.
Circuit breaker with earth leakage protection function, ELCB
– 4 main contacts (3 phases and 1 neutral)
– the maximum load of the circuit breaker is 25 A,
– Rated voltage 220 VAC and 30 mA circuit breaker
Three-phase circuit breaker, MCB
– 3 main contacts and load switch for maximum 25 A / 380 V,
– complete with fault simulator for L2 and L3 lines on the protection panel
Contactor
– 3 main contacts and 1 NO control contact, switching load maximum 25 A / 380 V,
– coil voltage 220 V / 50 Hz,
– complete with fault simulator for lines L1, L2 and contact coil on the protection panel.
Power On Delay Timer
– Time delay setting range: 0.1 – 30 ms,
– 3 main contacts and 3 control contacts, 2 NO, 1 NC,
– switching load maximum 10 A / 380 V,
– rated operating voltage 220 V / 50 Hz,
– complete with fault simulator for the L2 line, contact coil and auxiliary NO contact on the safety panel.
Switch
– 3 main input contacts, and 6 main output contacts,
– Switch load max. 3 A / 220 V
Push-button switches
– 2 pushbuttons, 2 NC contacts and 2 NO contacts,
– load on the switch maximum 250 V / 10 A,
– complete with fault simulator on the safety panel.
Mode switch
– Flush mounting type 250 V / 10 A,
– complete with fault simulator for NC/NO contacts on the cover panel.
Indicator lamp
– 3-Lamp Indicator,
– lamp shades colors: red, yellow, green.
– Rated voltage 220 VAC
Lamp base
– Rated voltage 220 VAC
Single-phase circuit breaker, MCB
– 1 main contact and switch load maximum 25A / 380 V
Single-phase AC motor
– Rated for motor operation, power 0.5 hp,
– current 4.2 A,
– rated voltage 220 VAC, 2 poles, frequency 50 Hz,
– Speed 1450 rpm
Power contactor
– 3 main contacts and 4 control contacts, 2 N0 and 2 NC,
– switching load maximum 25 A / 380 V,
– coil voltage 220 V / 50 Hz,
– complete with fault simulator for L2 line, contact coil and auxiliary normally open contact on the safety panel.
Thermostat
– 3-pole, single-phase overload cutoff,
– setting range: 1.25 – 2A,
– auxiliary contacts: 1 NC, 1 NO,
– complete with fault simulator for L1 line and NC/NO contact on the protection panel.
Single-key switch
– Flush mounting type 250 V / 10 A,
– complete with fault simulator on the cover panel.
Two-way switch
– Flush mounting type 250 V / 10 A,
– complete with fault simulator on the cover panel.
Schuko outlet
– Flush mount type 250 V / 16 A AC,
– 2-pole with grounded contact
Voltmeter
– Measuring range: 0 – 400 VAC,
– instrument: meter with moving coil, class 1.5,
– the device measures three-phase voltage.
Ammeter
– Measuring range: 0 – 6 A,
– instrument: moving coil meter, class 1.5,
– the device measures three-phase current.
RCD switch, ELCB
– 2 main contacts (1 for phase and 1 for neutral),
– maximum load on the switch: 25 A,
– rated voltage of 220 V,
– circuit breaker tripping current 30 mA
Three-phase AC motor
– Rated power: ¾ hp,
– Voltage 220 / 380 V,
– Y/D connection,
– 1400 rpm speed
Fluorescent lamp bases left
– Maximum voltage 250 V 50 Hz,
– maximum current: 3a,
– starter + plinth ;
– Power 20 – 40 W
Ballasts for fluorescent lamps
– Maximum voltage 250 V, 50 Hz,
– maximum current : 3A
Fluorescent lamp bases right
– Maximum voltage 250 VAC, 50 Hz,
– maximum current: 3 A
Capacitive load
– Maximum voltage 400 V,
– capacitors: 3 x 1 μF ; 3 x 2 μF ; 3 x 4 μF
Safety connecting wire 100 cm – 44 pcs.
Safety connecting wire 50 cm – 40 pcs.
Safety connecting wire 30 cm – 27 pcs.
Safety cross-connector – 50 pcs.
Manual of experiments – 1 pc.