{"id":2382,"date":"2022-12-21T18:09:52","date_gmt":"2022-12-21T15:09:52","guid":{"rendered":"https:\/\/phylab.tech\/product\/digital-and-modulation-simulator-stand\/"},"modified":"2023-06-07T10:38:54","modified_gmt":"2023-06-07T07:38:54","slug":"digital-modulation-techniques-trainer","status":"publish","type":"product","link":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/","title":{"rendered":"Digital Modulation Techniques Trainer"},"content":{"rendered":"<p>The composition of the set:<\/p>\n<p><b>Signal source generator:<\/b><br \/>\nSignal types: Sine: 512 kHz \/ Square: 20 kHz, 40 kHz, 80 kHz and 160 kHz<br \/>\nClock generator : 5 Hz &#8211; 1 kHz<br \/>\nWord generator: 8 bits with toggle switch<br \/>\nDisplay Indicator: LED<br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nEquipped with a voltage protection circuit  <\/p>\n<p><b>Amplitude modulation:<\/b><br \/>\nOperating voltage: +15V, +5V and -15VDC<br \/>\nConsists of modulator and demodulator units<br \/>\nEquipped with a voltage protection circuit  <\/p>\n<p><b>Frequency-key modulation:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nConsists of modulator and demodulator units<br \/>\nEquipped with a voltage protection circuit<\/p>\n<p><b>Phase modulation:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nConsists of modulator and demodulator units<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Differential phase modulation:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nIt consists of modulator and demodulator units.<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Quadrature phase modulation:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nIt consists of modulator and demodulator units.<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Pulse modulation unit (pulse amplitude modulation, pulse width modulation (PWM) and pulse phase modulation):<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nConsists of modulator and demodulator units<br \/>\nBuilt-in signal generator unit:<br \/>\nSinusoidal, frequency 20 Hz &#8211; 20 kHz<br \/>\nToothed, signal frequency 1.5 Hz &#8211; 10 kHz<br \/>\nClock, 4 Hz &#8211; 40 kHz signal frequency.<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Pulse-code modulation unit:<\/b><br \/>\nOperating voltage: +15V, +5V and -15VDC<br \/>\nIt consists of modulator and demodulator units.<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Time-division multiplexer:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nIt consists of a multiplexer, a demultiplexer and a clock oscillator.<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Frequency-division multiplexer:<\/b><br \/>\nOperating voltage: +15 V, +5 V and -15 VDC<br \/>\nIt consists of a multiplexer, a demultiplexer and a clock oscillator.<br \/>\n2 channels of information signal generator (sinusoidal)<br \/>\nFrequency 20 Hz &#8211; 20 kHz, 8 V in amplitude<br \/>\n2 channels of carrier signal generator (sinusoidal)<br \/>\nFrequency 200 Hz &#8211; 200 kHz, 8 V in amplitude<br \/>\nEquipped with a voltage protection circuit.  <\/p>\n<p><b>Power Supply:<\/b><br \/>\nOperating voltage: 220 V \/ 50 Hz AC. current<br \/>\nOutput voltage: +15 V, +5 V, +5 V AND -15 VDC<br \/>\nEquipped with a fuse and an AC connector cable (IEC type)<\/p>\n<p>Cross connector 40 pcs.<br \/>\nConnecting wire 30 cm, yellow 20 pcs.<br \/>\nConnecting wire 50 cm, black 2 pcs.<br \/>\nConnecting wire 50 cm, red 2 pcs.<br \/>\nConnecting wire 75 cm, yellow 10 pcs.<br \/>\nManual of experiments 1 pc.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Designed for the study of electronic communication systems in digital communication. The training package can be used to teach fundamental concept theory and practice in the field of digital communication. The system is made in the form of interchangeable panel modules. All inputs and outputs on each panel are equipped with 4-mm jacks for connection. Availability of connecting wires and jumpers for all experiments. Guide to experiments included.<\/p>\n","protected":false},"featured_media":1641,"comment_status":"closed","ping_status":"closed","template":"","meta":{"jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"product_cat":[259],"product_tag":[404,403,347],"class_list":["post-2382","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-laboratory-stands","product_tag-digital-modulation","product_tag-modulation","product_tag-stand"],"jetpack_publicize_connections":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v21.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Digital Modulation Techniques Trainer - PHYLAB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Digital Modulation Techniques Trainer\" \/>\n<meta property=\"og:description\" content=\"Designed for the study of electronic communication systems in digital communication. The training package can be used to teach fundamental concept theory and practice in the field of digital communication. The system is made in the form of interchangeable panel modules. All inputs and outputs on each panel are equipped with 4-mm jacks for connection. Availability of connecting wires and jumpers for all experiments. Guide to experiments included.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/\" \/>\n<meta property=\"og:site_name\" content=\"PHYLAB\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-07T07:38:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/phylab.tech\/wp-content\/uploads\/2022\/12\/TPU-11-Digital-Modulation-Techniques-Trainer.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Price\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Availability\" \/>\n\t<meta name=\"twitter:data2\" content=\"In stock\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/\",\"url\":\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/\",\"name\":\"Digital Modulation Techniques Trainer - PHYLAB\",\"isPartOf\":{\"@id\":\"https:\/\/phylab.tech\/en\/#website\"},\"datePublished\":\"2022-12-21T15:09:52+00:00\",\"dateModified\":\"2023-06-07T07:38:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430\",\"item\":\"https:\/\/phylab.tech\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u041a\u0430\u0442\u0430\u043b\u043e\u0433\",\"item\":\"https:\/\/phylab.tech\/catalog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Engineering-Specialties\",\"item\":\"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Stands\",\"item\":\"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/laboratory-stands\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Digital Modulation Techniques Trainer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/phylab.tech\/en\/#website\",\"url\":\"https:\/\/phylab.tech\/en\/\",\"name\":\"PHYLAB\",\"description\":\"\u0423\u0447\u0435\u0431\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0441\u0442\u0435\u043d\u0434\u044b, \u0442\u0440\u0435\u043d\u0430\u0436\u0435\u0440\u044b, \u043e\u0431\u0443\u0447\u0430\u044e\u0449\u0438\u0435 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u044b\",\"publisher\":{\"@id\":\"https:\/\/phylab.tech\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/phylab.tech\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/phylab.tech\/en\/#organization\",\"name\":\"JSC A2 SYSTEM\",\"url\":\"https:\/\/phylab.tech\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png\",\"contentUrl\":\"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png\",\"width\":188,\"height\":188,\"caption\":\"JSC A2 SYSTEM\"},\"image\":{\"@id\":\"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<meta property=\"product:price:amount\" content=\"0.00\" \/>\n<meta property=\"product:price:currency\" content=\"RUB\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"TPU-11\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Digital Modulation Techniques Trainer - PHYLAB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/","og_locale":"en_US","og_type":"article","og_title":"Digital Modulation Techniques Trainer","og_description":"Designed for the study of electronic communication systems in digital communication. The training package can be used to teach fundamental concept theory and practice in the field of digital communication. The system is made in the form of interchangeable panel modules. All inputs and outputs on each panel are equipped with 4-mm jacks for connection. Availability of connecting wires and jumpers for all experiments. Guide to experiments included.","og_url":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/","og_site_name":"PHYLAB","article_modified_time":"2023-06-07T07:38:54+00:00","og_image":[{"width":800,"height":533,"url":"https:\/\/phylab.tech\/wp-content\/uploads\/2022\/12\/TPU-11-Digital-Modulation-Techniques-Trainer.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Price":"","Availability":"In stock"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/","url":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/","name":"Digital Modulation Techniques Trainer - PHYLAB","isPartOf":{"@id":"https:\/\/phylab.tech\/en\/#website"},"datePublished":"2022-12-21T15:09:52+00:00","dateModified":"2023-06-07T07:38:54+00:00","breadcrumb":{"@id":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/phylab.tech\/en\/product\/digital-modulation-techniques-trainer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430","item":"https:\/\/phylab.tech\/en\/"},{"@type":"ListItem","position":2,"name":"\u041a\u0430\u0442\u0430\u043b\u043e\u0433","item":"https:\/\/phylab.tech\/catalog\/"},{"@type":"ListItem","position":3,"name":"Engineering-Specialties","item":"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/"},{"@type":"ListItem","position":4,"name":"Stands","item":"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/laboratory-stands\/"},{"@type":"ListItem","position":5,"name":"Digital Modulation Techniques Trainer"}]},{"@type":"WebSite","@id":"https:\/\/phylab.tech\/en\/#website","url":"https:\/\/phylab.tech\/en\/","name":"PHYLAB","description":"\u0423\u0447\u0435\u0431\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0441\u0442\u0435\u043d\u0434\u044b, \u0442\u0440\u0435\u043d\u0430\u0436\u0435\u0440\u044b, \u043e\u0431\u0443\u0447\u0430\u044e\u0449\u0438\u0435 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u044b","publisher":{"@id":"https:\/\/phylab.tech\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/phylab.tech\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/phylab.tech\/en\/#organization","name":"JSC A2 SYSTEM","url":"https:\/\/phylab.tech\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/","url":"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png","contentUrl":"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png","width":188,"height":188,"caption":"JSC A2 SYSTEM"},"image":{"@id":"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/"}}]},"product_price_amount":"0.00","product_price_currency":"RUB","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"TPU-11","product_condition":"new"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product\/2382","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/comments?post=2382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/media\/1641"}],"wp:attachment":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/media?parent=2382"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product_cat?post=2382"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product_tag?post=2382"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}