{"id":2394,"date":"2023-04-06T20:16:40","date_gmt":"2023-04-06T17:16:40","guid":{"rendered":"https:\/\/phylab.tech\/product\/experimental-installation-thermal-radiation\/"},"modified":"2023-04-06T20:16:40","modified_gmt":"2023-04-06T17:16:40","slug":"thermal-radiaton-system","status":"publish","type":"product","link":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/","title":{"rendered":"Experimental installation &#8220;Thermal radiation&#8221;"},"content":{"rendered":"<p>The experimental setup can be used to measure the intensity of thermal radiation emitted by an object with a given temperature. The setup consists of three main components: a Leslie cube with four different radiation surfaces (black surface, white surface, smooth aluminum surface, and rough aluminum surface), a lamp, and a radiation measurement sensor.<\/p>\n<p>Inside the cube is a lamp that acts as a heat source and a thermistor that measures the temperature inside the cube. The radiation sensor has three levels of measurement\/amplification (1x, 2.x and 4x). The lamp and radiation sensor are mounted on a guide rail with a scale, making it easy to track distance and displacement.<\/p>\n<p>Composition of the workplace:<\/p>\n<p>Thermal sensor for radiation measurement &#8211; 1 pc.<br \/>\nis used to detect thermal radiation emitted by the sample. It has three levels of measurement\/amplification (1x, 2,x and 4x). Powered by 2 1.5 V batteries each.<br \/>\nThe temperature sensor is a thermal sensor consisting of a set of thermocouples connected in series. It works on the basis of the Seebeck effect, namely the voltage difference resulting from the temperature difference between two conductors or semiconductors.<\/p>\n<p>Leslie cube with built-in heating lamp and thermistor &#8211; 1 set<br \/>\nHas four different radiation surfaces (black surface, white surface, smooth aluminum surface and rough aluminum surface) with a built-in lamp inside the cube. The lamp is used as a heat source. The presence of a regulator to change the radiation power of the lamp inside the cube. The presence of a 100 kOhm thermistor, which measures the temperature inside the cube. Cube size: 12 x 12 x 12 cm<\/p>\n<p>Incandescent lamp &#8211; 1 pc.<br \/>\nBuilt into the holder with the possibility of installing it on the rail. The lamp holder has a scale pointer for accurate positioning on the rail.<\/p>\n<p>Power supply &#8211; 1 pc.<br \/>\nElectronic overload or short-circuit protection; automatic electrical fuse with reset button and overload indicator LED.<br \/>\n4 mm connectors on the front panel of the device for connecting the load &#8211; 4 pcs.<br \/>\npower switch with indicator lamp.<br \/>\nInput voltage 100\/220 volts with fuse.<br \/>\nMaximum current 3 A<br \/>\nMaximum power 36W<br \/>\nAC\/DC output with 0 &#8211; 12 V step switch<br \/>\nExternal dimension 265 x 155 x 214 mm<\/p>\n<p>Digital multimeter &#8211; 2 pcs.<\/p>\n<p>Guide support &#8211; 2 pcs.<\/p>\n<p>Guide with scale 50 cm &#8211; 1 pc.<\/p>\n<p>Connecting wire 50 cm, red &#8211; 2 pcs.<br \/>\nConnecting wire 50 cm, black &#8211; 2 pcs.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The experimental setup can be used to measure the intensity of thermal radiation emitted by an object with a given temperature.<\/p>\n","protected":false},"featured_media":2133,"comment_status":"closed","ping_status":"closed","template":"","meta":{"jetpack_publicize_message":"","jetpack_is_tweetstorm":false,"jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false}}},"product_cat":[217],"product_tag":[422],"class_list":["post-2394","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-experimental-facilities","product_tag-heat-radiation"],"jetpack_publicize_connections":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.5 (Yoast SEO v21.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Experimental installation &quot;Thermal radiation&quot; - PHYLAB<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Experimental installation &quot;Thermal radiation&quot;\" \/>\n<meta property=\"og:description\" content=\"The experimental setup can be used to measure the intensity of thermal radiation emitted by an object with a given temperature.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/\" \/>\n<meta property=\"og:site_name\" content=\"PHYLAB\" \/>\n<meta property=\"og:image\" content=\"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/04\/HS_P_322-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1100\" \/>\n\t<meta property=\"og:image:height\" content=\"506\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Price\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Availability\" \/>\n\t<meta name=\"twitter:data2\" content=\"In stock\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/\",\"url\":\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/\",\"name\":\"Experimental installation \\\"Thermal radiation\\\" - PHYLAB\",\"isPartOf\":{\"@id\":\"https:\/\/phylab.tech\/en\/#website\"},\"datePublished\":\"2023-04-06T17:16:40+00:00\",\"dateModified\":\"2023-04-06T17:16:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430\",\"item\":\"https:\/\/phylab.tech\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u041a\u0430\u0442\u0430\u043b\u043e\u0433\",\"item\":\"https:\/\/phylab.tech\/catalog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Engineering-Specialties\",\"item\":\"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Experimental facilities\",\"item\":\"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/experimental-facilities\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Experimental installation &#171;Thermal radiation&#187;\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/phylab.tech\/en\/#website\",\"url\":\"https:\/\/phylab.tech\/en\/\",\"name\":\"PHYLAB\",\"description\":\"\u0423\u0447\u0435\u0431\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0441\u0442\u0435\u043d\u0434\u044b, \u0442\u0440\u0435\u043d\u0430\u0436\u0435\u0440\u044b, \u043e\u0431\u0443\u0447\u0430\u044e\u0449\u0438\u0435 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u044b\",\"publisher\":{\"@id\":\"https:\/\/phylab.tech\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/phylab.tech\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/phylab.tech\/en\/#organization\",\"name\":\"JSC A2 SYSTEM\",\"url\":\"https:\/\/phylab.tech\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png\",\"contentUrl\":\"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png\",\"width\":188,\"height\":188,\"caption\":\"JSC A2 SYSTEM\"},\"image\":{\"@id\":\"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<meta property=\"product:price:amount\" content=\"0.00\" \/>\n<meta property=\"product:price:currency\" content=\"RUB\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:retailer_item_id\" content=\"HS_P_322\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Experimental installation \"Thermal radiation\" - PHYLAB","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/","og_locale":"en_US","og_type":"article","og_title":"Experimental installation \"Thermal radiation\"","og_description":"The experimental setup can be used to measure the intensity of thermal radiation emitted by an object with a given temperature.","og_url":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/","og_site_name":"PHYLAB","og_image":[{"width":1100,"height":506,"url":"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/04\/HS_P_322-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Price":"","Availability":"In stock"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/","url":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/","name":"Experimental installation \"Thermal radiation\" - PHYLAB","isPartOf":{"@id":"https:\/\/phylab.tech\/en\/#website"},"datePublished":"2023-04-06T17:16:40+00:00","dateModified":"2023-04-06T17:16:40+00:00","breadcrumb":{"@id":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/phylab.tech\/en\/product\/thermal-radiaton-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0413\u043b\u0430\u0432\u043d\u0430\u044f \u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430","item":"https:\/\/phylab.tech\/en\/"},{"@type":"ListItem","position":2,"name":"\u041a\u0430\u0442\u0430\u043b\u043e\u0433","item":"https:\/\/phylab.tech\/catalog\/"},{"@type":"ListItem","position":3,"name":"Engineering-Specialties","item":"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/"},{"@type":"ListItem","position":4,"name":"Experimental facilities","item":"https:\/\/phylab.tech\/en\/product-category\/engineering-specialties\/experimental-facilities\/"},{"@type":"ListItem","position":5,"name":"Experimental installation &#171;Thermal radiation&#187;"}]},{"@type":"WebSite","@id":"https:\/\/phylab.tech\/en\/#website","url":"https:\/\/phylab.tech\/en\/","name":"PHYLAB","description":"\u0423\u0447\u0435\u0431\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435, \u0441\u0442\u0435\u043d\u0434\u044b, \u0442\u0440\u0435\u043d\u0430\u0436\u0435\u0440\u044b, \u043e\u0431\u0443\u0447\u0430\u044e\u0449\u0438\u0435 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0441\u044b","publisher":{"@id":"https:\/\/phylab.tech\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/phylab.tech\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/phylab.tech\/en\/#organization","name":"JSC A2 SYSTEM","url":"https:\/\/phylab.tech\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/","url":"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png","contentUrl":"https:\/\/phylab.tech\/wp-content\/uploads\/2023\/09\/phylab_logo_188\u0445188.png","width":188,"height":188,"caption":"JSC A2 SYSTEM"},"image":{"@id":"https:\/\/phylab.tech\/en\/#\/schema\/logo\/image\/"}}]},"product_price_amount":"0.00","product_price_currency":"RUB","og_availability":"instock","product_availability":"instock","product_retailer_item_id":"HS_P_322","product_condition":"new"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product\/2394","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/comments?post=2394"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/media\/2133"}],"wp:attachment":[{"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/media?parent=2394"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product_cat?post=2394"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/phylab.tech\/en\/wp-json\/wp\/v2\/product_tag?post=2394"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}