Skip to content
PHYLABPHYLAB
  • Engineering-Specialties
    • Stands
    • Engineering platform
    • Experimental facilities
    • Renewable energy
    • Industrial Robotics
  • Training sets
  • Mobile LAB
  • Quote Icon0
    X
    • No products in the list
    • Russian
    • Russian
Home / Mobile LAB / PHYSICS Mobile LAB

Direct Current Training Kit

Add to request
Already in quote list
Browse list
SKU: RML0104 Category: PHYSICS Mobile LAB Tags: direct current, electricity, training package
Каталог
  • Engineering-Specialties (90)
    • Engineering platform (29)
      • Electrical engineering (12)
      • Electronics (17)
    • Experimental facilities (25)
    • Industrial Robotics (1)
    • Renewable energy (2)
      • Ready to Work Series (1)
    • Stands (34)
  • Mobile LAB (21)
    • Alternative Energy Mobile LAB (1)
    • PHYSICS Mobile LAB (20)
  • Training sets (18)
    • Biology (1)
    • Chemistry (3)
    • Lab equipment (6)
    • Physics (8)
Список запроса цен

No products in the list

Вы смотрели
  • Training set "Air track" Experimental set-up "Air track"
  • Electric hot plate
  • Digital Modulation Techniques Trainer
  • Description
  • Experiments

Set composition:
Contact board 1 pc.
The number of dependent sectors with contacts is 35 pcs.
The number of independent contacts within the sector is 4 pcs.
Black connection wire type 1 – 2 pcs.
The length of the connecting wire type 1 – 25 cm, the connecting wire of red color type 2 – 1 pc.
The length of the connecting wire type 2 – 50 cm, the connecting wire of blue color type 3 – 1 pc.
The length of the connecting wire type 3 – 50 cm, the connecting wire of red color type 4 – 1 pc.
The length of the connecting wire type 4 – 75 cm, the connecting wire of blue color type 5 – 1 pc.
The length of the connecting wire type 5 is 75 cm, the packaged connector is 4 pcs.
Packaged straight wire 5 pcs. Packaged straight wire with 2 pcs. connector Packaged T-wire 4 pcs. Packaged T-wire with 1 pc. connector
Packaged corner wire 2 pcs. Packaged corner wire with 4 pcs connector. Packaged interrupted wire with connectors 1 pc.
Packaged switch ON/OFF 1 pc. Packaged two-way switch 2 pcs.
Packaged resistor type 1 – 1 pc.
resistance of the packaged resistor type 1 – 100 Ω
Packaged resistor type 2 – 1 pc.
resistance of the packaged resistor type 2 – 500 ohms
Packaged resistor type 3 – 1 pc. resistance of the packaged resistor type 3 – 1 kΩ
Packaged battery (accumulator) 2 pcs.
voltage of the packaged battery – 1.2 V, packaged wire with a sleeve 2 pcs. Enclosure connector for incandescent lamp 2 pcs.
Electrolysis capacity 1 pc.
set of conductors and dielectrics 1 pc.
Set of electrodes 1 pc.
Incandescent lamp type1 2 pcs.
Incandescent lamp type2 2 pcs.
Fusible red wire (coil) 1 pc.
High resistance blue wire (coil) 1 pc. copper wire (coil) 1 pc.
Crocodile clip with 4 pcs.
Holder with slot and hole 2 pcs.
Design requirements for enclosed elements:
body type molded
ABS plastic material
the image of the electrical component symbol on the surface of the housing
Kit Storage:
storage box with lid

Experiments of a set of teaching and learning materials:
Block “Basic principles”:
electric circuit
Flip switch
voltage
Daisy-chaining of voltage sources
parallel connection of voltage sources amperage
Conductors and dielectrics
whether liquids conduct electric current;
Block “Electrical resistance”:
Ohm’s law
a series of measurements according to Ohm’s law
application of Ohm’s law
Wires and their resistance
Resistivity of wires
ohmic resistor
An incandescent lamp is not an ohmic resistor
Series connection of incandescent lamps Series connection of ohmic resistors
voltage distribution, parallel connection of incandescent lamps, parallel connection of ohmic resistors, resistors in parallel/series electrical circuits;
Why do voltage sources connect in parallel?
Potentiometer model
internal resistance of the voltage source (output voltage)
internal resistance ammeter Wheatstone bridge
Block “Conversion of electrical energy into heat”:
electrical energy is converted into thermal, electrical energy and lighting, electrically conductive and rheostat wires;
Heat generation by wires with different cross-sectional diameters
fuse
Block “Work and Power”:
Incandescent lamp power
Electrical work
Block “Electrochemistry”:
electrochemical cell voltaic column electrolysis
Electrodeposition is a lead-acid battery model of the Volta series.

Related products

Quick View

PHYSICS Mobile LAB

AC Training Kit

Add to request
Already in quote list
Browse list
Quick View

PHYSICS Mobile LAB

Heat 2 training kit

Add to request
Already in quote list
Browse list
Quick View

Stands

Transformers Trainer

Add to request
Already in quote list
Browse list
Комплект для практических работ по химии (уровень 1)
Quick View

Chemistry

Chemistry Practice Kit (Level 1)

Add to request
Already in quote list
Browse list
Quick View

Stands

Electrical Installation Trainer

Add to request
Already in quote list
Browse list
Quick View

PHYSICS Mobile LAB

Vibrations and Waves kit

Add to request
Already in quote list
Browse list
Quick View

PHYSICS Mobile LAB

Mechanics Training Kit

Add to request
Already in quote list
Browse list
Учебный набор "Гидростатика и термодинамика"
Quick View

Physics

Laboratory kit on hydrostatics and thermodynamics

Add to request
Already in quote list
Browse list
About company

PhyLab - This trademark belongs to JSC "A2 SYSTEM"

Контакты
Joint-stock company «A2 SYSTEM»
Russia, 123610, Moscow, Krasnopresnenskaya naberezhnaya, 12, gate 6, office 709.
tel.: +7(495)131-20-20
e-mail: info@a2sys.tech
Copyright 2026 © JSC «A2 SYSTEM»
  • English English
    • Русский Русский
    • English English
  • Engineering-Specialties
    • Stands
    • Engineering platform
    • Experimental facilities
    • Renewable energy
    • Industrial Robotics
  • Training sets
  • Mobile LAB
  • Login

Login

Lost your password?